100 amp sub panel ground wire size - Nov 12, 2019 at 20:47. 1. You should expect a voltage drop of 1.45% at 60A on #1Al wire. That is fine. Even at continuous-max 80A Vdrop will be 1.94%. You should not plan to run higher than 80A. This is more than adequate. Even the 3% zealots would not recommend a wire size bump here. - Harper - Reinstate Monica.

 
When your 200-amp service is complete, you'll have a 2/0 AWG copper wire with a 4 AWG ground wire or a 4/0 AWG aluminum/copper-clad wire with a 2 AWG aluminum grounding wire. With 200-amp service, your panel can handle a higher electrical load—allowing you to run multiple appliances at once without interruption.. Lh 480 flight status

Mobile broadband subscriptions in Sub-Saharan Africa are forecast to grow by 16% a year to 880 million subs by 2023 It is easy to glaze over the impact of the mobile phone in Afric...We offer the #1 Electrical Exam Prep ProgramFREE VERSION https://electricalcodecoach.com/free-exam-prep-programPRO VERSION https://www.electricalexamcoach.co...Ground size for 100 amp sub panel 200ft away. Ask Question. Asked 5 years, 3 months ago. Modified 5 years, 3 months ago. Viewed 25k times. 5. I would like …Ever since Adam posted his (sort of) cordless workspace, I planned to get my own rat's nest of dusty, under-the-desk wires in check. Once I snagged myself one of those swanky cord ...For a 100-amp sub-panel, a #8 AWG copper wire is recommended for the ground connection, but it’s always best to consult local codes and regulations to ensure compliance. Installing the correct cable size for the ground connection is essential for safety and proper function, as it helps prevent electrical fires, shorts, and other hazards.Jul 6, 2004. #8. Re: 4 Wire sub-panel...HELP 250.122 (B) requires the EGC to be increased in size when the ungrounded conductors are increased in size. If we assume that the 4 AWG are copper and protected by a 50 amp breaker they have been increased in size.The Correct Wire Sizes for a 50A Sub Panel. According to the size chart recommendations from the 2002 edition of the NEC, the minimum wire for 50 amps should be 6 AWG for copper. For aluminum, it should at least be 4 AWG. However, these answers assume that there's no voltage drop to consider. The NEC considers a 5% voltage drop as the maximum ...This video demonstrates How to wire and properly ground a 30 Amp sub-panel. Perform at your own risk. If not comfortable, do not perform.Typical sizes of wires for 100 Amp Service are 4 AWG or 2 AWG for copper wiring and 2 AWG, 1 AWG, or 1/0 AWG for aluminum or copper-clad wiring. These sizes are also used for direct burial. When choosing 100 amp service wire size, remember that a 100 amp circuit at 240V can proceed up to 24,000W of electricity.For a 100 amp sub panel located within 100 feet of the main panel, the National Electrical Code (NEC) recommends using a conductor of at least 3 AWG copper or 1 AWG …1802 posts · Joined 2008. #8 · Jan 24, 2010. I would suggest to consider to do wires in conduit rather than direct bury cable. Electrical conduit is cheap. Wire for conduit vs UF bury cable may be cheaper. Conduit is 18" burial vs. 24" burial for UF cable - another 6" at the bottom of a long trench is a lot of extra work.Sep 17, 2023 · The size of the ground wire for a 100 amp service depends on the type of wiring used and the distance between the electrical service panel and the grounding electrode. It is best to consult a licensed electrician to determine the appropriate size. Wire Size For 100 Amp Sub Panel 150 Feet Away. Wire Ampacity (150 ft away) = 125A × 1.3 = 162.5 Amps. There is a need of wire with 162.5 ampacity for sending 100 amps current at 150 feet distance.The minimum ground wire size for a 100-amp circuit is typically #4 copper or #2 aluminum, as per NEC guidelines. ... What size wire do I need for a 50-amp sub panel? The wire size needed for a 50-amp subpanel depends on factors like the distance and the type of subpanel. Typically, #6 copper or #4 aluminum conductors are used.Install a 100 amp sub panel with ease. electrical real life application. I am installing an electrical sub panel on an apartment building for a laundry area....Seems the old forum said I could use 4/3 w/G NM conductor for 100 AMP sub panel (being fed from 100 AMP new service in this residential dwelling... Menu. Home. Forums. ... Conductor size for 100 amp sub panel? Thread starter vliposky; Start date Apr 4, 2007; Status Not open for further replies. ... Yes and also #2 NM 4 wire . Dennis Alwon ...A 50-amp breaker uses four wires, two of which are hot feeds of 120 volts. This results in 50 amps at 120 volts for each leg. Voltage is the measurement of differences in electric ...Mar 23, 2023 · Typical sizes of wires for 100 Amp Service are 4 AWG or 2 AWG for copper wiring and 2 AWG, 1 AWG, or 1/0 AWG for aluminum or copper-clad wiring. These sizes are also used for direct burial. When choosing 100 amp service wire size, remember that a 100 amp circuit at 240V can proceed up to 24,000W of electricity. I agree with Rob. Look at the wording of 250.122(B). The "increased in size" sentence was recently revised to clarify that it means "increased from a size that would have been sufficient for the required ampacity." In your case, a 3/0 would have had sufficient ampacity for a 200 amp load, and you used a larger wire than that.I'm going to be running a circuit out to a detatched garage for a 100 amp sub-panel. I'm going to use 4 conductor USE aluminum for the feeder underground (2 hot legs, a neutral, and a seperate ground). Can I use #2 Al for my feeder per section 310.15(B)(6) or do I have to use #1 Al per 310.16?For convenience I'm installing a 100 amp subpanel within one foot of the main panel, which is 200 amps. NO new circuits are being added; only moved from main panel to subpanel. Three THHN #3 wires and a #8 EGC wire will be run through 1 …1. I would like to run a sub panel out to my garage to run an 80 gal (4hp) compressor. -- I have a 200 amp shut-off panel on the outside of my house which runs to a 200 amp breaker panel in the house. I was told to think of the outside box as the "main" panel and the one in the house as a "sub-panel." So, I am essentially running a sub panel ...A 100 amp, 24-space subpanel is a good middle ground. Use thick, quality copper feeder wires between the main panel and subpanel. Undersized wires cause problems. Follow the ampacity tables to select the proper wire size. Properly ground the subpanel with ground rods and thick wire. Good grounding is critical for safety and preventing ...There is a ground wire. It is either #6 or #4, I cannot remember. It is THWN-2. The bonding screw is not connected in the 100 amp subpanel that I want to upgrade to 150 and it is grounded to a six foot grounding rod at the subpanel. My plan is if the wire can handle it then I will replace the 100 amp panel with a 150 amp panel.Updated on February 15, 2024. According to the NEC, the wire size for 200 amp service is a 3/0 AWG copper wire or 4/0 AWG aluminum wire. You should increase wire size by 20% for every extra 100 feet run to account for voltage drop. For a 200-amp cable size spanning over 200 feet, choose a 500 kcmil copper wire or a 1000 kcmil aluminum wire.From the above table, if we apply the 83% rule, then the minimum required conductor size must be calculated for 83% of 100 Amps i.e., 83 Amps. So, the 100 Amp Wire Size with an 83% rule is AWG 4 for Copper Conductors and AWG 2 for both Aluminum and Copper-Clad Aluminum Conductors. Apart from the Service Entrance conductors, the feeder wires i.e ...So, you can always choose a lower AWG if the load exceeds the breaker's capacity and the distance gets longer than 100 feet. Ground wire size for 70 amps. ... The wire size is no different from the breaker and service for a 70 amp sub panel. A 2 AWG or a 4 AWG wire is the ideal choice for a 70 amps sub panel. ...Huntsville, AL, USA. Aug 20, 2012. #1. I went to Lowe's today to get a feeder for a single-phase 100 amp load center. We usually use copper in the field & I knew off hand that I could use #3 AWG, but since I was on a side job I looked in the code book for the Al size of equal or greater ampacity. I was of the opinion that I should use the 75 ...Wire size for 100 amp basement sub-panel. Have a 200 amp main in my attached garage. I am adding a 100 amp sub-panel in my basement to run all my basement circuits (2 bedrooms, office, living room, wet bar, bathroom). I have a panel with breaker set in the basement, and already have the 100 amp breaker to go in the main in the garage, …100A sub panel wire size ... to install a code legal 100 amp sub panel. You contracted for a 100 amp sub panel, not an 80 amp panel. There are processes that the license can go through to appeal the inspectors ruling. In the meantime though you are without an inspected panel. ... Ok thanks the inspector already failed me for the 2awg not being ...The minimum conductor size allowed is #1 aluminum, which is 83.7 kcmil in cross-section. The minimum ground wire size allowed is #6 aluminum, which is 26.3 kcmil in cross-section. When you enlarge the conductors for any reason, you must also enlarge the ground in proportion. So the ground is 26.3/83.7 = 31.4% of the conductors.At first, I wasn't sure if I could complete the wiring and install of the 100 amp sub panel. I started with just agreeing to dig the trench for the 100 amp w...1) 3-#3 copper for 100 amp sub panel. 1-#8 EGC. 2) The ground wire EGC must be run with the feeder conductors. So you will be pulling 4 wires H-H-N-G. #8 Ground wire is sufficient. Minimum. 3) No, the EGC is connected to the grounding/neutral buss bar in the main panels. Bonding only occurs at the service.You've ripped a movie on your laptop, and now want it on that fancy new home theater PC next to your TV. If you've got the time, wiring your house with Cat-5e cable could make tran...When determining feeder conductor size, you'll want to consider the "lowest temperature rating of any connected termination, conductor, or device" as per National Electrical Code (NEC) Article 110.14(C).While the cable/wire may be rated at 90°C, you'll likely find that the terminals are rated at 75°C, or not labeled at all. 110.14(C)(1)(a) tells us, that since we're working with 100 amperes ...No, the minimum size ground wire for a 100 amp sub panel is #8 copper wire or #6 aluminum wire. Using a smaller size wire can be dangerous and may not …Generally, for a 100 amp sub panel, you'll need a grounding conductor that is at least #8 AWG copper or #6 AWG aluminum. First and foremost, you'll need to check the local electrical code requirements. When it comes to determining the ground size for a 100 amp sub panel, there are a few factors to consider. So, let's dive in!When selecting a wire size for a 100 amp sub panel, it is crucial to choose a wire with an ampacity that exceeds the current rating of the panel. This ensures that the wire can safely handle the maximum load without overheating. In general, for a 100 amp sub panel, a wire size of at least 3/0 AWG copper or 4/0 AWG aluminum would be suitable.100 Amp Sub Panel Wire Size. • A 100 amp sub panel requires a minimum 6-gauge wire for the connection between the main panel and the sub panel. • The ground wire should be 8-gauge for a 100 amp sub panel. • The neutral wire should be 1-gauge for a 100 amp sub panel. • All wires should be copper and rated for use in wet or dry locations.Wire size depends on breaker size (can be larger than the breaker but can't be smaller). ... GFCI in a 3-wire sub panel with bonded neutral and ground. 1. ... Un-conduit 3-3-3-5 CU SER feeder cable through studs for 100 amp sub panel 4 ft away. 2. Wire type from meter base to panel, conduit end to end, underground, and through a …But if the sub-panel is located in a detached building, let us say the garage, then you also need to "ground the panel" by running a wire from its ground bar to planet Earth (e.g., to a ground rod or two). That wire would be the GEC that Bob mentioned, and it is sized per 250.66.The Square D by Schneider Electric QO Value Pack 100 Amp 24-Space 24-Circuit Indoor Main Breaker Plug-on Neutral Load Center includes the cover and a selection of standard Square D QO breakers. It is UL Listed for residential, commercial and industrial power distribution. This load center is built with a shielded, tin-plated, copper bus bar that is plated for reliability. QO load centers are ...The grounding wire for the leading service and breaker box will also work for the sub-panel. For a 100 amp sub panel, you can use an 8 AWG or 6 AWG wire. However, you can also use the same wire size as the hot and neutral wires.Yes, it is possible to run a 100 amp subpanel off a 100 amp main panel. However, it's crucial to perform a detailed load calculation to ensure the main panel has sufficient capacity to accommodate the total electrical load of both panels and associated circuits. ... What Size Wire Do I Need for 100 Amp Service 100 Feet Away. For a 100 amp ...The sub panel is 100 amp but what is the calculated load. If you are looking for the wire size for 100 amps at 240 then 2/0 alum. would work. For copper you need #1. For the EGC then look at T. 250.122. "If the doors of perception were cleansed everything would appear to man as it is, Infinite. William Blake. SaveShare.Boeing notified 16 customers of a potential wiring issue on recently delivered 737 Max jets, the latest problem for the jet. Just months after global aviation regulators lifted the...In this case, instead of using a 2/0 copper wire, you should use 300 kcmil copper with only a 2.78% voltage drop. This suggested size wire for a 200 amp panel will work for both single-phase and three-phase installations. On the other hand, if you are tight on budget, you can use 500 kcmil aluminum.The type of colored wire you use should be decided by the amperage of your subpanel. For example, a 50 amp panel uses #8 THHN wire. Get some snacks and drinks. It could easily cost you 2 hours to wire the subpanel to your detached garage — you want to stay energized and hydrated especially if you are working during the summer time.We also offer single conductor XHHW-2 Aluminum Building Wire. Our most popular aluminum wire for 100 amps service would be our #2 AWG XHHW-2 Aluminum Building Wire & our #1 AWG XHHW-2 Aluminum Building Wire. Click here to view pricing and specs on our XHHW-2 Aluminum Building Wire. Wire And Cable Your Way always recommends consulting with a ...Updated on February 15, 2024. According to the NEC, the wire size for 200 amp service is a 3/0 AWG copper wire or 4/0 AWG aluminum wire. You should increase wire size by 20% for every extra 100 feet run to account for voltage drop. For a 200-amp cable size spanning over 200 feet, choose a 500 kcmil copper wire or a 1000 kcmil aluminum wire.The next step is to wire back from the subpanel to the main panel. You'll need to attach the hot feeder wire to a new circuit breaker (in our case a 200-volt one). Once that is done, connect the neutral and ground wires from the feeder cable to the corresponding bus bars in the main panel. Lastly, snap the feeder breaker into the main panel ...Reader Paul says he's got a little trick that helps keep his headphone cables from getting tangled into knots: Reader Paul says he's got a little trick that helps keep his headphon...The wire size for AMP service is broken down in the following very useful chart. According to the table above, a 100 amp service necessitates a wire size of around 1.25 inches. Copper is used on wire #4, while aluminum is used on wire #2. The optimal size for larger conductors to maintain the fill level inside the conductor is 1.5 to 2 inches.My plan is to run 240 volt 100 AMP power to detached garage. I have 200 AMP Panel in basement of house. Main question is wiring for the run. 50 feet of the run will be in house crawl space/basement. 50 feet will need to be buried 24" in ground. Can I run direct buried cable for the whole distance if so what size wire?If a cold water pipe comes into the metal building it too would need a grounding electrode wire and clamp and bonding jumper over the PRV. Also from the disconnect you would run SER cable just like in step 1, to a main lug sub panel. 4/0 Al @ 75 deg is good up to 180 Amps [See NEC Table 310.15(B)(16)].Doing a brief search shows that it's somewhere around 10-13 amps at 240. The nameplate on the pump motor should say how many amps it will draw. You could probably "get by" with 12 ga copper, but I'd run 10 ga just to be safe. Put it in conduit in the ground. You'll need two hots, a neutral and a ground.Even a 12-space panel will run out of spaces before it runs out of power. So I would advise something more like a 24-space, even a 30 would not be excessive. Breaker spaces are laughably cheap compared to the cost of having to change out a panel because the originally-chosen one was too small. There's no worry if the bus rating of the panel ...To run a 100 amp sub panel off a 200 amp main panel, feed the ground wire through the PVC conduit and secure it to the main panel’s ground bar. Secure the other end of the ground wire to the sub panel’s ground bar. Next, wiring a subpanel with 3 wires typically needs you to feed the feeder wire through the PVC conduit.You can do what you want if you have a 100 amp or smaller feeder breaker in the main. The sub panel will require a 4 wire connection and the non insulated conductor can only be used as a ground. The neutral requires insulation as do the hot conductors, in the sub the neutral needs to be isolated from ground.I am installing a new sub-panel fed from my main house panel. The new sub-panel is a 240V/125A panel without a main breaker, and the neutral and ground bus are connected. I plan on using 2 #2/0 with a #4 neutral and #4 ground. The cable will be direct buried, so no conduit. Do I need to install a ground rod for the new sub-panel, or make sure ...What Size Ground Do I Need For 100 Amp Sub Panel? A subpanel that caters to 100 amp circuit breakers needs a ground wire size of #6 aluminum or #8 copper. But it's possible to get by with a #4 copper or #2 aluminum wire for that service panel. Conclusion .The National Electric Code (NEC) requires a #4 American Wire Gauge (AWG) copper wire for sub-panels. If using an aluminum or copper-clad aluminum wire, a #2 AWG wire can be used. The minimum conduit size is 1.25 inches and a schedule 40 or 80 PVC electrical conduit is specified for lines run underground. However, wiring requirements change ...In fact, the most appropriate wire size for 100 amp service is the #1 AWG wire with a 130 amp median capacity. To understand why this is, and what wire size you need for 100 …40 Amp Wire (100 ft distance) = 50A × 1.2 = 60A Ampacity. That means that we need an AWG wire with at least 60A amperage to send 40 amps 100 feet away from the sub panel. The #8 AWG wire with 50A amperage will not be sufficient here. We need to get the next size wire: #6 AWG wire. This wire has a 65A ampacity and can handle 60 amps quite …For 150 amps, 1 gauge wire is required. 4 to 6 gauge wire rated at 150 amps will suffice for the ground wire. Bear in mind that as the current, gain, and voltage of your appliances increase, the wires become smaller. Because 150 amps is a higher current, it necessitates a smaller gauge wire.This is a sub panel. It is being fed and protected by a 100a breaker. 8-104 (1) says the rating of the feeder is the breaker or wire whichever is smaller, therefore it is 100a rated. No loads were given, even if they were, you still have a tub that is 100a rated, and a breaker that is 100a rated.Always use copper for a ground wire (and never as a neutral wire). ... For a six-space panel used indoors, a 100-amp wire size is needed, while a two-space outdoor panel can work with a 60, 100, or 200-amp wire. Always check the product rating to make sure you’re using the correct wires. ... You can run a 100-amp sub-panel from a 200 …NEC Annex C, Table C10 says 3 XHHW's will fit in 2". I know wires will fit in smaller but going with 60% fill requirements and pulling ease. Even 2" will suffice. But go 2 1/2", it's easier to pull the wire. 3" is clearly not needed.Square D offers a variety of sizes to meet various applications within a home. 1 Phase, 3 Wire, 120/240VAC. 6 Spaces, expandable to 12 circuits maximum with the use of QO Tandem breakers. Type 1 Indoor Enclosure with surface mounted trim and no door. CSA approved for vertical, horizontal or inverted mounting. Accepts aluminum or copper conductors.North America is the location. The sign is 120 volt, 20 AMP in a dedicated circuit There will be three 120 volt, 30 watt lights, one 115 feet from the panel, one 100 feet from the panel, and one twenty feet from the panel. We have considered setting another pole but would rather not.When calculating wire size for 200 feet of 100 amp service, use the following equation: ( Note that both conductors in Equation 1 must be 6 AWG. If there is only one conductor, divide by 2 instead). 1/0 = 4.73Volt per foot-3 Maximum Amps you can safely install:' 1 ohm. = (4.7V x 0) (500W) / Resistance Value .Mar 15, 2023 · There is no code that prohibits a 100-amp subpanel from being protected by a 90-amp breaker. Since your plans do not include any electricity-guzzling heavy equipment, your 100-amp subpanel can be supplied with #2 cable if you protect the subpanel with a 90-amp breaker in the main panel. Nov 12, 2019 at 20:47. 1. You should expect a voltage drop of 1.45% at 60A on #1Al wire. That is fine. Even at continuous-max 80A Vdrop will be 1.94%. You should not plan to run higher than 80A. This is more than adequate. Even the 3% zealots would not recommend a wire size bump here. – Harper - Reinstate Monica.Subpanel will power yard lights, bbq island, and workshop/shed (160sq ft with basic contractors table saw, drill press, etc.). Current Logic: For a 100amp panel, it looks like this would typically require 3 AWG THWN wire (seems that SER isn't rated for use in conduit and I've seen 3AWG (all references to wire are copper) recommended on this ...Your wires are undersized for Full 100 Amps unless you use #2 copper, and #2 copper will cost a LOT. (#3 will actually work, but good luck finding that in stock, and it will still cost hugely) You can do 90A on 2-2-2-4 aluminum "Mobile home feeder" which pulls just fine in 1-1/4" conduit and is very affordable.Wire size depends on breaker size (can be larger than the breaker but can't be smaller). ... GFCI in a 3-wire sub panel with bonded neutral and ground. 1. ... Un-conduit 3-3-3-5 CU SER feeder cable through studs for 100 amp sub panel 4 ft away. 2. Wire type from meter base to panel, conduit end to end, underground, and through a crawl space. 0.But 75 would be enough so it's best to jump up to 90 or 100. 75a = 2 awg wire with 2.56% voltage drop this would also handle 90 amps to go up to 100 amp 1 awg wire would be needed. With older panels finding anything larger than is doubtful. With max loads listed #2 and a 90 amp breaker would give additional room. - Ed Beal.But 75 would be enough so it’s best to jump up to 90 or 100. 75a = 2 awg wire with 2.56% voltage drop this would also handle 90 amps to go up to 100 amp 1 awg wire would be needed. With older panels finding anything larger than is doubtful. With max loads listed #2 and a 90 amp breaker would give additional room. – Ed Beal.

The panel must have a separate neutral and ground bar. The neutral bar will be tied to ground/chassis, and you'll need to remove that tie. The panel needs to be at least 40A obviously; larger is fine. A 200A panel can handle 40A. Since you're in the same building, main-lug is fine, main breaker is also OK, and the main breaker size doesn't …. Woe it's me crossword

100 amp sub panel ground wire size

For that service would use URD Aluminum 4 conductor cable (need 2 hot, neutral and should have separate ground to shop, grounds isolated from neutrals in shop panel. for 300 feet for 100 amp rated service I would use Aluminum direct burial 1/0-1/0-1/0-1/0, the forth can be as low as #4 for the ground (but also in conduit, even if in conduit ... The proper wire size must be determined for a 60-amp sub-panel to be installed safely and effectively. The requirements of the particular application, distance, and voltage drop all play a role in the wire size. Choosing the appropriate gauge reduces the possibility of electrical hazards and guarantees peak performance. Knowing the correct wire size is […]You'll want to get a 24-space or 30-space, 100A or 125A, main breaker panel for the greenhouse and fit a matching accessory ground bar or two to it as well as removing the neutral-to-ground bonding screw or strap from the panel. This way, neutral and ground are separated at the subpanel, as they should be, so that normally flowing power doesn't ...The main panel should be grounded (probably with 2 grounding rods) and the grounded (neutral) and grounding buses should be bonded in the main panel. The subpanel probably isn't far enough away from the main to require its own grounding rod (s), but regardless, it does require a 4 wire feed from the main panel (2 ungrounded …A 40 amp breaker needs a minimum of 8 gauge, larger gauge won't hurt. If using 39 amps (actual) at the same time, then you might need to use a 50 amp breaker with 6 gauge wire minimum. If sub panel is in the same building then I think you only need the ground wire back to main. - crip659. Jul 12, 2022 at 23:08.Wire size depends on breaker size (can be larger than the breaker but can't be smaller). ... GFCI in a 3-wire sub panel with bonded neutral and ground. 1. ... Un-conduit 3-3-3-5 CU SER feeder cable through studs for 100 amp sub panel 4 ft away. 2. Wire type from meter base to panel, conduit end to end, underground, and through a …350 Amps. 350 kcmil Copper Wire. 500 kcmil Aluminum Wire. 400 Amps. 400 kcmil Copper Wire. 600 kcmil Aluminum Wire. This table is quite easy to use. For example, let's say you are trying to figure out the feeder wire size for 300 amp service. By checking this table, you can see you will need either 4/0 AWG copper wire or 300 kcmil aluminum ...I installed a 100 Amp subpanel in my metal garage and used a Ryobi bandsaw to cut the aluminum wires. I also framed around a door and tapcons were used to an...When selecting a wire size for a 100 amp sub panel, it is crucial to choose a wire with an ampacity that exceeds the current rating of the panel. This ensures that the wire can safely handle the maximum load without overheating. In general, for a 100 amp sub panel, a wire size of at least 3/0 AWG copper or 4/0 AWG aluminum would be suitable.The National Electric Code (NEC) requires a #4 American Wire Gauge (AWG) copper wire for sub-panels. If using an aluminum or copper-clad aluminum wire, a #2 AWG wire can be used. The minimum conduit size is 1.25 inches and a schedule 40 or 80 PVC electrical conduit is specified for lines run underground. However, wiring requirements change ...The calculator is designed to accept the total line voltage and current of the combined three cables. The equation for the area of a single wire is modified to: A = \frac {\sqrt 3 I \varrho L} {V} A = V 3I ϱL. The factor of \sqrt 3 3 is needed to convert between the system's phase current and line current.At that point you will go 4-wire, and since the new extension is 4-wire, you are Code complete. Save money other ways. The current subpanel has the same breaker size as the intended feed to the sub-subpanel. As such, the $40 subpanel breaker feeding the sub-sub is redundant. Get rid of it. If the subpanel has feed-thru lugs, you can just tap them.Required Wire Size: #0AWG (1/0 AWG) Cupper (#3/0 for Aluminum) based on the above calculation and AWG chart and tables based on NEC, the right size wire for 100 amp circuit at a distance of 100 feet from the main panel to subpanel is 1/0 AWG (AKA #0 AWG). It means, an the wire having ampacity of 150A is sufficient to deliver 100A to the the ....