Hayward heater hs code - "b2" Code stands for "Gas valve sensed as "ON" error. If gas valve is powered when it should be off, the heater. will shut down and go into lock out.

 
Clean the hayward heater regularly to prevent any debris buildup, which can trigger the if code. Remove leaves, sticks, and other objects from the heater. Check the air filter and clean or replace it as needed. A dirty filter restricts airflow and can cause the heater to overheat, resulting in the if code.. Strongsville car crash

Remove front & rear panels Remove wires from limit switches. Step 13. Remove the 4 screws from the bottom of the front and rear panels and pull up and out to remove each one. Step 14. Use needle nose pliers to remove the 2 red wires from each of the high limit switches. Remove wires from water pressure switch.hayward pool heater H-350 codes SF & HS. Would like to know. hayward pool heater H-350 codes SF & HS. Would like to know how to test temp sensor.Dealing with the Hayward Heater HS IO code can be challenging, but with the right knowledge, preventive measures, and a willingness to explore advanced options, you can maintain a reliable and safe heating system for your pool or spa. Remember that safety should always be a top priority when working with gas appliances, and don't hesitate to ...Jul 3, 2022 · I have a Hayward 135k pool heater that I just installed. I have an HS code on the display. It runs for about 1 minute then displays this code. The temp starts at 50 degrees and climbs rapidly to 56 th … read more Hayward HeatPro Heat Pump Parts HP21404T, HP21004T, HP21254T, HP31154T. Starting from $44.99. Delivery. FREE Shipping with +$100 Purchase. Shop Now. Hayward Heatmaster HM Models 280-406 Pool Heater Parts. Starting from $28.99. Delivery. FREE Shipping with +$100 Purchase.View and Download Hayward H150 installation, operation and service manual online. H150 swimming pool heater pdf manual download. Also for: H250, H200, H300, H350, H400, H210.The Hayward Pool Heater SF Code is a safety feature that prevents the pool heater from over-heating. The code stands for “Safety Fault” and is displayed when the temperature in the heater exceeds 110 degrees Fahrenheit (43°C). It will shut off power to the pool heater until it can cool down to a safe temperature.I have a Hayward Goldline pro logic system with a Hayward heater model H400FD. I recently replaced the heater's display board. ... Get bd code heater 7 years old opened up pool worked fine then got code ... My Hayward heater shows two errors SF and HS.Is it something.I have a Hayward 135k pool heater that I just installed. I have an HS code on the display. It runs for about 1 minute then displays this code. The temp starts at 50 degrees and climbs rapidly to 56 th … read morePage 4 of 7 Hayward City Hall 777 B Street Hayward CA, 94541-5007 Phone: 510-583-4140 Website: www.hayward-ca.gov Permit Center Hours: Please see website for operating hours c. A homeowner, unless they are also a qualified draftsperson or designer, can prepare plans for the following project types: like-for-like kitchen and bathroomExplore Hayward Pool's Dealer Warranty Claims - Submit and Track Claims for Hayward Pool Products. Simplify warranty processes with our user-friendly platform. Get peace of mind and exceptional customer support. ... Learn How Solar Pool Heaters Work; Learn About Hayward. At Hayward, we're more than just equipment. Learn more. Hayward Insights.If the heater can't get rid of the products of combustion, excess heat and/or flames etc will roll out the bottom by the burner tray. There is a safety switch that will detect that and prevent the heater from firing. Heater fires, switch then detects the problem a few seconds later and shuts it down. If it doesn't shut it down you will cook the ...I bought a new thermistor IDXLTER1930 to replace old defective one (code SF) in my Hayward H300 pool heater. New one reads about 20 deg F too low. For example, when pool is around 70 deg which I can t …The Lo on a Hayward heater means "low." When the Lo setting is selected, the heater runs at a lower speed, which can help conserve energy. In some cases, the Lo setting may indicate a malfunction or another issue with the heater. If you notice your Hayward heater displaying an LO code, it is important to check the manual or contact customer ...I have a Hayward 135k pool heater that I just installed. I have an HS code on the display. It runs for about 1 minute then displays this code. The temp starts at 50 degrees and climbs rapidly to 56 then the unit shuts off and displays the code. The water temp is about 45 degrees. I'm wondering if it's a water temp issue or a flow issue.It is perfectly normal operation to show the FLO code even while the heater is in the OFF position because the control panel and display are still operational. From the manual: All AquaCal heaters represented within this manual are designed to operate successfully at flow rates of 30-to-70 gallons-per-minute (GPM).I bought a new thermistor IDXLTER1930 to replace old defective one (code SF) in my Hayward H300 pool heater. New one reads about 20 deg F too low. For example, when pool is around 70 deg which I can t …View online or download Hayward HDF275 Troubleshooting Manual. ... Hayward Manuals; Heater; HDF275; Hayward HDF275 Manuals. Manuals and User Guides for Hayward HDF275. We have 1 Hayward HDF275 manual available for free PDF download: Troubleshooting ... SF" or "HS" Code. 41. PF" Code. 42. HF" Code. 43. LO: Code. 44. IF" Code. 48. AC" Code. 50 ...Meaning of Display Codes Service Analyzer Codes Most problems will be detected by the service analyzer and a code will be displayed on the digital display of your heater. Display Meaning of codes The desired programmed temperature point is lower than 60°F (15°C). Page 20: Troubleshooting Troubleshooting The pool heater is not running. Universal HC Series - Dual Fuel 400k BTU. Hayward. SKU: HDF400. The industry’s smallest footprint heater allows replacement of almost any heater in an existing pad with the efficient reliability of the new Universal HC Series dual-fuel technology heater from Hayward®. Add to Compare. Add to Export. Overview. The Lo on a Hayward heater means "low." When the Lo setting is selected, the heater runs at a lower speed, which can help conserve energy. In some cases, the Lo setting may indicate a malfunction or another issue with the heater. If you notice your Hayward heater displaying an LO code, it is important to check the manual or contact customer ...I have a Hayward 135k pool heater that I just installed. I have an HS code on the display. It runs for about 1 minute then displays this code. The temp starts at 50 degrees and climbs rapidly to 56 then the unit shuts off and displays the code. The water temp is about 45 degrees. I'm wondering if it's a water temp issue or a flow issue.The Lo Code Hayward Heater is made of high quality materials that make it durable and long lasting. It is also very easy to install and does not require any special tools or skills. If you have a Hayward heater and it’s displaying the “Lo” code, don’t panic! This simply means that the heater’s water temperature is too low.Here I go over some of the most common problems that affect these Hayward, formerly Summit Heat pump or thermopump pool heaters. Flo (no flow) and LP (low pr...NJ. Aug 7, 2021. #1. Hello, I have a H150FDN pool heater. It's worked all summer so far, but last week I noticed that it would turn on for a few minutes then turn off and show Lo. The filter is clean and the output is strong. I ordered a new pressure switch, but in the meantime I took the two wires that connect to the switch and made a jumper ...What does HS mean on my Hayward pool heater? HS code is telling you that the water output temp is too high. The code does not necessarily mean the sensor is bad but, is instead telling you there is a problem in the operation of the heater. Do you have enough water flow thru the unit to prevent the water temp from getting to high?Adjust the water flow or call a professional if the pressure is too low. Clean the Filter: A dirty or clogged filter can cause Hayward Heater CE Code errors. Clean the filter thoroughly and replace it if necessary. This will improve the heater’s efficiency and prevent future issues. Inspect the Ignition System: If the above steps do not ...HS Code 85161080 - Electric, water, heaters. Electric water heaters and immersion heaters (excl. instantaneous water heaters) Supplements and exceptions: - Notes to the Section. - Notes to the Chapter. German. French. Can be used for an export declaration. (Combined Nomenclature, Customs Tariff Number)Service LED ON: “b3” Code. “b3” Code stands for “Gas valve sensed as “OFF” error. If gas valve is unpowered but flame is sensed, the blower will run for 5 seconds then start a …Get the monthly weather forecast for Roquetas de Mar, Andalusia, Spain, including daily high/low, historical averages, to help you plan ahead.kbran333 I'm new here Posts: 1 Joined: Thu 10 Jun, 2021 10:43 My Pool: Above ground 27' x 4' round pool. Hayward PowerFlo LX 1.5HP pump, Swimpro Voyager 150 filter system. Hayward Universal H-Series heater 150,000 BTUHayward pool heater H5 code is one of the common error codes on Haywad pool heater. The H5 code identifies the water temperature sensing error report from inlet sensor. The root reason behind H5 or HS error includes inadequate water flow, clogged water filter, and incorrect setting of the thermostat.I have a Hayward 135k pool heater that I just installed. I have an HS code on the display. It runs for about 1 minute then displays this code. The temp starts at 50 degrees and climbs rapidly to 56 then the unit shuts off and displays the code. The water temp is about 45 degrees. I'm wondering if it's a water temp issue or a flow issue.Mar 16, 2018. #1. We have a Hayward H400IDL2 pool heater that ignites and runs normally at start up. After about 10 minutes it begins to repeatedly cycle off and on before finally throwing an IF code. We've had multiple service calls from 2 different pool companies and have replaced the gas valve, flame sensor, igniter and control board.The IF code on your Hayward pool heater points to an ignition problem, usually occurring when the heater fails to ignite or the ignition process is interrupted. Advertisment. Read more The Ultimate Guide to Stronger Floors. However, This could result from gas supply issues, ignition control module problems, or defective igniters. Timely ...SPECIFICATIONS AND DIMENSIONS H500FD H400FD H250FD H200FD H150FD BTU/hr 500,000 399,900 250,000 199,900 150,000 Thermal efficiency 83% 84% 84% 83% 82.7%Ensure the proper installation of the main circuit board within the heater. Check the short ground and high voltage issue and take steps to prevent it. 5. Circuit Board’s Faulty Fuse. Another factor responsible for displaying the Hayward pool heater ce code is the faulty or blown fuse in the heater’s circuit board.Error Code AC. This error occurs when your blower vacuum switch is found …I have a Hayward 135k pool heater that I just installed. I have an HS code on the display. It runs for about 1 minute then displays this code. The temp starts at 50 degrees and climbs rapidly to 56 th … read moreHayward pool heater H5 code is one of the common error codes on Haywad pool heater. The H5 code identifies the water temperature sensing error report from inlet sensor. The root reason behind H5 or HS error includes inadequate water flow, clogged water filter, and incorrect setting of the thermostat. See moreFixing the Hayward Heater AO Code: Now that we've identified the common causes, let's explore the fixes to resolve the AO code issue: Inspect and Clean the Air Intake: Start by turning off the heater and inspecting the air intake. Remove any debris or obstructions that may be blocking the airflow. Ensure the intake is clean and clear.The HS code for 'roasted caffeinated coffee' would be (0901.21). The general rules. The general rules will guide traders in classifying their goods which will give them the most appropriate HS code. There are six general rules that guide traders to classify their goods. GR1.Identify your product's 6 digit HTS Code or HS Code from the above list. Now, you have to identify the 8 digit code of your product as all the import duty tariffs in the United States HTS are listed at 8 digit HTS Code. Click on the HTS 6 you have selected for your product, it will take you to a list of 8-10 digit HTS Codes where you will also ...We have a commercial inground pool with a 250000 btu Hayward H Series Propane Heater for the spa and we just added a 140k Hayward Heat Pro Heat pump to pool. ... We have a hayward electric heat pump and it is showing a code of E03 and the heater leaks and it is ... inquiries related to stress, high blood pressure, drinking and …Double Feature - Hungry? Hayward pool heater with ignition failure along with multiple issues. 9 years old. Time for a replacement. Cost effective solution i...Diagnostic Codes For Hayward Heat PumpJul 3, 2022 · I have a Hayward 135k pool heater that I just installed. I have an HS code on the display. It runs for about 1 minute then displays this code. The temp starts at 50 degrees and climbs rapidly to 56 th … read more We have a commercial inground pool with a 250000 btu Hayward H Series Propane Heater for the spa and we just added a 140k Hayward Heat Pro Heat pump to pool. ... i have an almost new hayward summit heat pump pool heater, shows steadt f-5 code for defrost mode, ...Step 1 Step 2 Verify the heater's power LED is illuminated, and put the heater is Using the up and down arrows adjust the heater to the desired the desired mode. Page 13 How To: Set Clock Follow these steps to adjust the Clock Settings. Note: blocked off areas of the display represent flashing numbers.Solar water heaters could help cut your utility bills. Visit HowStuffWorks to learn about solar water heaters. Advertisement Heating up water accounts for a good chunk of a home's ...CN Code : A 2000 W ceramic heater with an electric fan. It is used for space heating. It has additional functions: wide-angle oscillation, overheating protection, built-in tipping switch, thermostat adjustable with a knob and two heating levels. Packed in a cardboard box. Dimensions: 196mm x 196mm x 452mm. Weight 2.7 kg.The HS code on your Hayward heater is a temperature-sensing error. The code helps you to be aware of any unusual temperature changes in your spa or pool …Haywood heater. Gas 3 yrs old. Just set up for the season. Code h 5 - Answered by a verified Pool and Spa Expert. ... It is likely and HS code as I do not believe your heater has and H5 code. This indicated an over temp condition of the water. ... Just turned on our new Hayward pool heater model ABG135 for the 1st time.Home - Trouble Free Pool | Trouble Free PoolHayward pool heater service code 56 Hayward pool heater service code 56.POOL HEATER TEMPERATURE 🔐 UNLOCK !!! HAYWARD ,may work for different models,Hayward® is America's first choice for residential and commercial swimming pool and spa equipment. We manufacture the Totally Hayward™ System and sell our products direct to wholesalers. ... Pump, Filter, Heater, Lights, & Whole Goods Tech Support. 1 (908) 355-7995 (U.S.) Contact us by letter: Hayward Holdings, Inc. 1415 Vantage Park Drive ...Have a Hayward Pool Heater. Model H250 FDP. Have a code "HF" ( Flame Sensor ). Display also showing "service". Cleaned unit. ... I have a hayward gas pool heater model H400ed2, the heater will go on and get hot for about one min. and then shut off for about one minute and then go back on again.Adjust the water flow or call a professional if the pressure is too low. Clean the Filter: A dirty or clogged filter can cause Hayward Heater CE Code errors. Clean the filter thoroughly and replace it if necessary. This will improve the heater’s efficiency and prevent future issues. Inspect the Ignition System: If the above steps do not ...Haywood heater. Gas 3 yrs old. Just set up for the season. Code h 5 - Answered by a verified Pool and Spa Expert. ... It is likely and HS code as I do not believe your heater has and H5 code. This indicated an over temp condition of the water. ... Just turned on our new Hayward pool heater model ABG135 for the 1st time.Meaning of Display Codes 17 Troubleshooting 18 Requesting Assistance or Service 20 Maintenance 21 Winterizing 21 Hayward® Heat Pump Pool Heater Limited Warranty 22 International Warranty 23 Notes 24 Warranty Card Registration 25 Table of contents OWNER'S MANUAL. 2 Thank you for buyingMay 31, 2023 · Hayward Pool Heater IF Code What Does IF Code Mean? The Hayward Pool Heater IF code indicates an ignition failure. This means that the heater was unable to ignite the gas properly, preventing it from operating as intended. IF Code Quick Troubleshooting Steps. Refers to an ignition failure. Check gas supply and ensure valves are open. Hayward Universal H-Series Low NOx Induced Draft Pool & Spa Heater | 400,000 BTU | Natural Gas | W3H400FDN. The Hayward Universal H-Series gas heater is the "universal" energy efficient remedy for any new …Jul 21, 2013 47,820 Northern NJ Pool Size 35000 Surface Plaster Chlorine Salt Water Generator SWG Type Pentair Intellichlor IC-60 Our network of certified personnel can help you build your pool, recommend a product, repair a faulty product, and test your water. Find a professional near you. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools. LO CODE FIXES. Step 1: Inspecting the Water Pressure Switch Wiring. Step 2: Testing Water Pressure Switch Continuity. Step 3: Pressure Switch Adjustment (If Required) Step 4: Temperature Limit Switch Wiring Inspection. Step 5: Continuity Test for Temperature Limit Switches."b2" Code stands for "Gas valve sensed as "ON" error. If gas valve is powered when it should be off, the heater. will shut down and go into lock out.By clicking "Find Related HS Code" button above, you can find 6 digits universal HS Code (which is valid for almost all countries in the world) and declarable codes for EU, UK, USA, Japan, China, India and Turkey (e.g. 10 digits TARIC code for EU countries or HTSUS code for USA) of "portable space heaters". You can also find customs duty rates ...Web the 60 code is really bo meaning bypass operation in which your heater's internal thermostat is bypassed so as to control the set temperature by your. Web the hayward heater hs code indicates that either your water temperature has exceeded a maximum of 104°f or the water temperature is changing at an unusual.SPECIFICATIONS AND DIMENSIONS H500FD H400FD H250FD H200FD H150FD BTU/hr 500,000 399,900 250,000 199,900 150,000 Thermal efficiency 83% 84% 84% 83% 82.7%The Hayward HeatPro 140K Electric Heat Pump is a high-efficiency heater, gives you the ideal water temperature while using 80% less energy than natural gas heaters. It offers an alternative way to heat your pool that is safe, reliable, and energy efficient. Hayward HeatPro Electric Heater takes the heat from the surrounding air and uses it to ...Heater Hayward Universal H-Series Low NOx Service & Installation Manual. Pool and spa/hot tub heaters (64 pages) Heater Hayward H150FDAU Owner's Manual. ... "SF" or "HS" Code 40-41 UHS Gas and Electrical Connections 9-11 9. "PF" Code 42-43 How To: Pg. Page 4: Icb And Fuse Board Layout Integrated Control Board Layout (ICB) Remote ...Below is a list of all Diagnostic Codes for the UHS Heater. Diagnostic Code Description AC Blower Vacuum Switch closed AO Blower Vacuum Switch open BD Bad board or secondary high voltage fault CE Communication Error Between Control Module and Display Interface Assembly EE Bad board HF Flame present with Gas Valve not energized.Heater will not power up Pages 14-22 ... BD Code Pages 33-34 EE and CE Codes Page 35 IO and SB Codes Page 36 SF and HS Codes Page 37 HS and PF Codes Page 38 HF Code Page 39 LO Code Pages 40-43 IF Code Pages 44-46 AC Code Page 47 AO Code Page 48-50 Temperature Lock Out Page 51 ... Hayward Part # FDXLFSKF30 (Qty. 10) Step 1:Adjust the water flow or call a professional if the pressure is too low. Clean the Filter: A dirty or clogged filter can cause Hayward Heater CE Code errors. Clean the filter thoroughly and replace it if necessary. This will improve the heater’s efficiency and prevent future issues. Inspect the Ignition System: If the above steps do not ...Residential: Heaters. Hayward has an advanced lineup of heaters and heat-cool pumps to deliver the ultimate control of water temperature and efficiency. Learn More. Download Assets. 49 Items.Below is a list of all Diagnostic Codes for the UHS Heater. Diagnostic Code Description AC Blower Vacuum Switch closed AO Blower Vacuum Switch open BD Bad board or secondary high voltage fault CE Communication Error Between Control Module and Display Interface Assembly EE Bad board HF Flame present with Gas Valve not energized.Hayward 250 pool heater throwing AO code. Replaced control board, blower motor, pressure switch, igniter. Still not turning on. … read more. Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts.Identify your product's 6 digit HTS Code or HS Code from the above list. Now, you have to identify the 8 digit code of your product as all the import duty tariffs in the United States HTS are listed at 8 digit HTS Code. Click on the HTS 6 you have selected for your product, it will take you to a list of 8-10 digit HTS Codes where you will also ... HeatPro In Ground Heat Pump, 140,000 BTUs, Square Platform. Hayward has an advanced lineup of gas heat and electric heat and heat+chill solutions to deliver the ultimate control of your water temperature. 1. 8516. Electric Instantaneous Or Storage Water Heaters And Immersion Heaters; Electric Space Heating Apparatus And Soil Heatin. 85168000. Electric heating resistors. 2. 8422. Dish Washing Machines; Machinery For Cleaning Or Drying Bottles Or Other Containers; Machinery For Filling, Closing, Se. 84229090.The Hayward pool heater spa mode is designed to maintain a specific "spa-like" temperature in the pool. To use this mode, enable "Spa mode" from the control panel, set the required temperature, and let the pool heater warm the water. Once ready, test the water. This process is a joy to behold for those who want to soak themselves in ...Universal H-Series Natural Gas 150,000 BTU Low NOx. Hayward. SKU: W3H150FDN. The Universal H-Series is an energy efficient, high performance, installation adaptable commitment to the pool service professional. Add to Compare. Add to Export.Heater will not power up Pages 14-22 ... BD Code Pages 33-34 EE and CE Codes Page 35 IO and SB Codes Page 36 SF and HS Codes Page 37 HS and PF Codes Page 38 HF Code Page 39 LO Code Pages 40-43 IF Code Pages 44-46 AC Code Page 47 AO Code Page 48-50 Temperature Lock Out Page 51 ... Hayward Part # FDXLFSKF30 (Qty. 10) Step 1:Pool heater started find when pool first opened up this spring. Turned off heater for past 2 weeks then went to start it up. The heater is stuck in standby mode and the service light is on. Pushing any of the buttons doesnt do anything.Here you’ll gain easy access to information regarding your favorite Hayward products. Whether you are looking for a Quick Reference Guide, troubleshooting steps, or simply wish to view one of our product support videos, you have come to the right place.

HS Code Goods/Service discription SGST CGST IGST CESS Conditions; 7322: Radiators for central heating, not electrically heated, and parts thereof, of iron or steel; air heaters and hot air 20 distributors (including distributors which can also distribute fresh or conditioned air), not electrically heated, incorporating a motor-driven fan or blower, and parts thereof, of iron or steel. How to play pls donate in roblox 2023

hayward heater hs code

hayward pool heater H-350 codes SF & HS. Would like to know. hayward pool heater H-350 codes SF & HS. Would like to know how to test temp sensor. I have 15 volts on all 3 wires at control panel ...My hayward heater is showing a CE code. I've replaced the display and ignition boards and it's still showing a CE - Answered by a verified Pool and Spa Expert We use cookies to give you the best possible experience on our website.It is perfectly normal operation to show the FLO code even while the heater is in the OFF position because the control panel and display are still operational. From the manual: All AquaCal heaters represented within this manual are designed to operate successfully at flow rates of 30-to-70 gallons-per-minute (GPM).hayward pool heater H-350 codes SF & HS. Would like to know. hayward pool heater H-350 codes SF & HS. Would like to know how to test temp sensor. I have 15 volts on all 3 wires at control panel ...My Hayward spa heater (installed 2018) is not heating the water and is displaying this LO code. I have read every troubleshooting guide and watched every video I could find. My diagnostics included: 1. Cleaned the filters, even ran the pump without the filters - still LO 2. Checked wires at pressure switch for continuity - still LO 3.Hayward W3H150FDP Universal H-Series 150,000 BTU Propane Pool and Spa Heater for In-Ground Pools and Spas. dummy. Raypak 014779 PR106AENC 105000 BTU Natural Gas Pool Heater. dummy. FibroHeat FibroPool Swimming Pool Heat Pump - FH255 55,000 BTU - for Above and In Ground Pools and Spas - High Efficiency, All Electric Heater - No Natural Gas or ...Page 41: Sf" Or "Hs" Code 8. Service LED ON: “SF” OR “HS” Code The “HS” (High Sense (water temperature)) will appear if the water sensor is reading above 105° OR if the …Conclusion. In conclusion, troubleshooting the Hayward pool heater code 1F can be done by following a few simple steps. First, check the water flow to ensure there aren't any blockages or restrictions. Next, inspect the pressure switch for any signs of damage or malfunction. If necessary, clean the heat exchanger to remove any debris or buildup. HeatPro In Ground Heat Pump, 140,000 BTUs, Square Platform. Hayward has an advanced lineup of gas heat and electric heat and heat+chill solutions to deliver the ultimate control of your water temperature. Web the 60 code is really bo meaning bypass operation in which your heater's internal thermostat is bypassed so as to control the set temperature by your. Web the hayward heater hs code indicates that either your water temperature has exceeded a maximum of 104°f or the water temperature is changing at an unusual.heater and to all metal parts of swimming pool or spa, and to all electrical equipment, metal piping (except gas piping), and conduit within 5 ft. (1.5 m) of inside walls of swimming pool or spa. IMPORTANT -Refer-ence NEC codes for all wiring standards including, but not limited to, grounding, bonding and other general wiring procedures.Check your filter pressure differential and skimmer baskets. With variable speed pumps, ensure you have the RPM of the filter pump set at 2200 RPM. Check and clean the heaters' heat exchanger. Remove and inspect the High limit sensors, and there are two located in the header of the heater.Press and hold the "Up" and "Down" buttons simultaneously, according to the Stanley Louis Company. Hold the buttons until the indicator light rapidly flashes and the digital display shows the maximum temperature-lock setting. Typically, this is in the range of 90-degrees F. Release both buttons. Select the desired water temperature with the ....

Popular Topics