How to extend electrical wire without junction box - 3 Answers. Sorted by: You are sunk. Wire that short can't be spliced or extended. The wire must be able to come out beyond the surface of the box at least 3". You will need to reroute these cables to a different junction box somewhere the wiring is able reach with the needed spare length inside the box.

 
For intermediate-sized electrical wires such as #14 copper wire (a 15-Amp electrical circuit) or #12 copper wire (a 20-Amp electrical circuit), you can usually strip about 3/4" of bare wire (special stripping tools are available that won't damage the wire or you can work carefully with wire cutters or a knife), and you can twist your wires .... Little alchemy 2 recipe

The usual solution is to use a junction box, with or without anything else in the box. For example, if your cable goes to a light fixture and you want to replace it with another light fixture a few feet away, connect the old & new cables with wire nuts inside the existing box, cover it with a blank plate, and run the new cable to a new box ...How to splice or connect broken and cut electrical wires together. In this video I go over 10 different ways to repair or reconnect a chewed or damaged elect...Step One. SWITCH OFF ELECTRICITY AT THE MAINS - You will require two 30amp junction boxes and a length of 2.5mm2 cable.The best way of using junction boxes to extend a ring circuit, is to find the length of cable between the two sockets on the existing ring closest to the desired extension area. Once located it can be cut in the …To use, insert the cable into the hole of the cable ripper until it is roughly 6 inches from the end of the cable. Pressing lightly on the sides of the cable ripper, move the tool around the cable to slice through the sheathing. Trim away the severed portions of the cable using a wire stripper.Insert the Cable Into the Box. Thread the stripped nonmetallic sheathed cable into the old work box, making sure the sheathing is secured under the clamping tab (for a PVC box) or the clamping bar (for a phenolic resin/fiberglass box). Make sure to leave about 6 to 7 inches of exposed wires.A junction box is a container used to house electrical connections, protecting them from damage and preventing the risk of electrical fires. It serves as a central point for electrical wiring, allowing for easy access and maintenance. A well-designed junction box is essential for any electrical system.Mar 31, 2023 · Baseboard heaters. Many permanently installed appliances, such as kitchen vent hoods, dishwashers, and hot water heaters, also don't require junction boxes. With these devices, if the electrical wires will be exposed or run outside of a wall, ceiling, or floor cavity, the wires must be contained inside some type of flexible conduit or be metal ... Suppose your cable conductors are 2.5 ㎟ use the blue crimp. Place the blue crimp in the crimping tool and fix the prepared conductor to one side of the crimp, ensuring that the wires are inside the metal section. Apply pressure to the crimping tool and give a solid squeeze to make a solid crimped joint. Now place the blue crimp back into the ...NM Cable 2 & 3 Wire Splice kit. This splice and tap kit is designed for NM cables such as Romex brand NM cable and provides a fast and reliable means for splicing or tapping 2-wire and 3 wire NM cables w/ground – up to 300 volts. The manufacturers of these kits generally claim the product will work with NM cables manufactured after 1990.To install this type of clamp, insert the threaded end into a knockout hole in the box, then thread on the locknut onto the threaded end from inside the box. Tighten the nut with pliers. Insert the cable through the clamp saddle and into the box, and tighten the screws on the saddle to secure the cable.Nov 26, 2021 · Making junction boxes for less than 2 dollars (assuming you have the tools and wire nuts/push connectors already) :-) ---This is a re-upload where at the en... Photo 1: The easy but less elegant way. Remove the old switch (power off) and screw the extender box on top of the old box. Then install the new switch and cover plate on the extension box. Photo 2: The harder but more attractive option. Disconnect the old switch and label all the wires (power off). Saw out the old box, remove the wires and set ...To make a run for a ceiling fixture, push an electrician's fish tape through the switch hole and down to the source receptacle. Use electrical tape to strap about 6 inches of cable to the fish tape and pull it up through the switch hole. Cut it free from the fish tape and leave about 12 inches on both ends.Options to Lengthen the Wires: Option 1: Check for extra wire or a service loop behind the box. Gently pull on the wires using pliers to draw more length into the box if available. Option 2: Access the cable feeding into the …Sep 27, 2023 ... ... Junction Box Accessibility [NEC 210.11(C)(3) & 210.52(D)] [] Length of Free Conductors @ Outlets [NEC 300.14] [] 1/4" of cable jacket in the box ...For intermediate-sized electrical wires such as #14 copper wire (a 15-Amp electrical circuit) or #12 copper wire (a 20-Amp electrical circuit), you can usually strip about 3/4" of bare wire (special stripping tools are available that won't damage the wire or you can work carefully with wire cutters or a knife), and you can twist your wires ...Extending an electrical outlet box is a relatively straightforward process. There are several methods to choose from, depending on the situation. Here are the most common methods: The first method involves using splicing blocks. These are small blocks that allow you to join two or more wires together without cutting them.The thousand of other questions are the ones that electricians, electrical engineers, and other professionals in the electrical industry would have known about, and would have understood the answers to, as part of their years of training. In your case, perhaps there are fewer unanswered questions of which you are, at present, unaware.Thank you, but aesthetically i do not want to see the conduit or any wiring. could one chisel and make a trench (so to speak) and chisel away deep enough to put in a junction box without it protruding almost 3 inches. Again this would only be done if the building management approves. Thanks again! – Bring the cables into the box through the clamps. Make a mark on the cable about ½ inch beyond the clamp, withdraw the cable, measure and cut the conductors about 6 inches beyond the mark, then strip the cable’s plastic or metal sheathing back to the mark. Bring the cable back into the box. If it’s a metal box, tighten the cable clamps ... Make sure to cut the wire cleanly and without damaging the insulation. Set the chandelier aside for now. Prepare the extension cord: Cut the male end of the extension cord, leaving a few inches of wire. Strip the insulation from the end of the extension cord wires using wire strippers. Connect the wires: Twist together the exposed end of the ...Installing a Tyco Electronics no junction box splice connector.https://www.grainger.com/category/electrical/electrical-supplies/wire-connectors/non-metallic-...Probably the easiest route for you would be to install a retrofit gang box to the left of the stud with the other gang box (if there's room, it's hard to tell from the photographs), run the existing wire into it, then run a new, longer, wire from the gang box to the receptacle. Connect the two wires with electrical nuts, and finally, cover the ...When it comes to electrical wiring, following the latest codes and regulations is crucial for ensuring safety and preventing potential hazards. Over time, these codes undergo updat... We would like to show you a description here but the site won’t allow us. Electrical wiring color code standards are crucial for ensuring the safety and functionality of electrical systems in buildings and homes. These color codes help electricians and h...NM Cable 2 & 3 Wire Splice kit. This splice and tap kit is designed for NM cables such as Romex brand NM cable and provides a fast and reliable means for splicing or tapping 2-wire and 3 wire NM cables w/ground – up to 300 volts. The manufacturers of these kits generally claim the product will work with NM cables manufactured after 1990.Sep 14, 2018 ... ... or join electrical wires using wire nuts.I will show you how to properly strip off the outer insulation without damaging the wires inside.The thousand of other questions are the ones that electricians, electrical engineers, and other professionals in the electrical industry would have known about, and would have understood the answers to, as part of their years of training. In your case, perhaps there are fewer unanswered questions of which you are, at present, unaware.When it comes to electrical projects, the wire gauge table is an essential tool. It helps you determine the right size of wire for your project. Knowing how to use a wire gauge tab...Mar 28, 2018 ... "SHOCKING" New Way to Fix Short Wires In an Electrical Box to Code | Very Important ... How to Extend Wire in Attic ... how to wire a junction box ....Then, remove about ½” of the plastic sheathing from the individual copper wires. Examine the wiring for signs of damage. Look for burnt wire insulation, cut wires, nicks, or bite marks. Remove any damaged areas before you begin splicing. Slide a piece of shrink tubing over the wire you’re splicing as you’ll need it once you complete the ...Electrical wiring color code standards are crucial for ensuring the safety and functionality of electrical systems in buildings and homes. These color codes help electricians and h...Junction boxes are essential components of any electrical system and they serve an important purpose. Unfortunately, they can become damaged over time and need to be replaced. However, if you are looking for a more cost-effective way to extend the life of your junction box without having to purchase a new one, then you’ve come to the …May 11, 2023 · With a pry bar or screwdriver, coax the box away from the stud enough to see the mounting nail or screw. With a metal blade on a reciprocating, oscillating, or keyhole saw, cut the nail or screw. Be careful to avoid hitting the electrical cable. Pull the box out of the hole while leaving the wire in the wall cavity. RVs are a popular choice for those seeking the freedom of the open road. With their compact size and all-in-one functionality, they provide a comfortable home away from home. Howev...Then, remove about ½” of the plastic sheathing from the individual copper wires. Examine the wiring for signs of damage. Look for burnt wire insulation, cut wires, nicks, or bite marks. Remove any damaged areas before you begin splicing. Slide a piece of shrink tubing over the wire you’re splicing as you’ll need it once you complete the ...Exception: Where nonmetallic-sheathed cable or multi-conductor Type UF cable is used with single gang boxes not larger than a nominal size 57 mm × 100 mm (21⁄4 in. × 4 in.) mounted in walls or ceilings, and where the cable is fastened within 200 mm (8 in.) of the box measured along the sheath and where the sheath extends through a cable ...You can’t splice it in the wall or use a j-box that would be buried (code). You will need to back pull it and replace the run to the fixture. Concealed splicing is not permitted. The only correct way to splice is replace the section and/or do the splice in …Nov 3, 2020 · NM Cable 2 & 3 Wire Splice kit. This splice and tap kit is designed for NM cables such as Romex brand NM cable and provides a fast and reliable means for splicing or tapping 2-wire and 3 wire NM cables w/ground – up to 300 volts. The manufacturers of these kits generally claim the product will work with NM cables manufactured after 1990. For intermediate-sized electrical wires such as #14 copper wire (a 15-Amp electrical circuit) or #12 copper wire (a 20-Amp electrical circuit), you can usually strip about 3/4" of bare wire (special stripping tools are available that won't damage the wire or you can work carefully with wire cutters or a knife), and you can twist your wires ...For intermediate-sized electrical wires such as #14 copper wire (a 15-Amp electrical circuit) or #12 copper wire (a 20-Amp electrical circuit), you can usually strip about 3/4" of bare wire (special stripping tools are available that won't damage the wire or you can work carefully with wire cutters or a knife), and you can twist your wires ...Electrical codes generally require that all electrical devices, and the wiring connections to those devices, must be enclosed in an approved electrical box. Often known as a junction box, this metal or plastic box includes a cover to protect the wiring within and protect you from the wiring. This rule is demonstrated nicely by wall switches, …The process of extending electrical wires with a junction box is fairly simple and can be done by anyone with a basic knowledge of electrical wiring. In this article, we'll explore the steps involved in extending electrical wires from an existing circuit with a junction box and offer some tips to ensure the job is done correctly.Photo 1: The easy but less elegant way. Remove the old switch (power off) and screw the extender box on top of the old box. Then install the new switch and cover plate on the extension box. Photo 2: The harder but more attractive option. Disconnect the old switch and label all the wires (power off). Saw out the old box, remove the wires and set ...However, the existing Romex is too short to comfortably be threaded through a hole in the stud/shim and into the fan box on the other side. I was going to leave the old box in place, using it as a pure junction box (no fixture/switch/outlet) and running a short length of Romex from this box, through the stud/shim, to the fan box on the other side.pendant light| ceiling hook. We installed the hook in the ceiling at the location where we wanted the fixture. First we pre-drilled a small hole and then twisted in the hook, which basically has a screw attached to it. Thankfully our beadboard is made of solid wood, so we felt comfortable that it was strong enough to support the fixture.If your around-the-house to-do list includes an ambitious DIY electrical project, be it installing a light fixture, replacing a switch, or extending electrical wires to add another outlet in... Bring the cables into the box through the clamps. Make a mark on the cable about ½ inch beyond the clamp, withdraw the cable, measure and cut the conductors about 6 inches beyond the mark, then strip the cable’s plastic or metal sheathing back to the mark. Bring the cable back into the box. If it’s a metal box, tighten the cable clamps ... Family Handyman. Making Connections Outside Electrical Boxes. Mistake: No electrical box | Never connect wires outside of electrical boxes. Junction boxes (or a …There are two ways to enlarge an existing box without tearing the wall open. By the DIY experts of The Family Handyman Magazine. Make room for a new device. …It's the same in Canada actually. We do have codes for not using a panel as a junction box for "conductors feeding through to other apparatus". And another for not filling the wiring space more than 75%. 12-3032 (1) (2) But for sure we can use wire nuts in a panel. pjholguin, RRF, B-Nabs and 1 other person.Watch on. Yes, it is possible to extend wire without using a junction box. If you have to extend an electrical wire, you can use an extension cord, also known as a power cord, to power the wire without using a junction box. Extension cords are simple electrical devices that allow you to extend the length of a wire without having to cut or ...Inside wall junction boxes to extend circuits or add outlets and switches; Ceiling electrical boxes tying fixtures to wiring from below; ... Terminal blocks allow easy connecting and disconnecting of wires without re-stripping. Helpful for troubleshooting or swapping out wires down the road.You Can’t Splice It In The Wall. Romex is a type of cable which is used in electrical wiring. However, because it consists of a number of wires which are tightly bound together, you cannot simply cut it and splice it into your wall. Instead, you will need to access junction boxes so that you can make the required connections.Splice Ground First. Hold the bare copper ground wires with one hand, and line up the ends so they’re even. Twist the ends of the wires together two or three times with lineman’s pliers. If any of the wires are not solid metal but have multiple fine threads or strands, skip this step. Spin on a wire nut until tight.If your around-the-house to-do list includes an ambitious DIY electrical project, be it installing a light fixture, replacing a switch, or extending electrical wires to add another outlet in...Pictures and step-by-step instruction for splicing household electrical wiring to extend a circuit.Make sure to cut the wire cleanly and without damaging the insulation. Set the chandelier aside for now. Prepare the extension cord: Cut the male end of the extension cord, leaving a few inches of wire. Strip the insulation from the end of the extension cord wires using wire strippers. Connect the wires: Twist together the exposed end of the ...Mar 17, 2022 · WAGO 221 Lever Nut Kit: https://amzn.to/3LuMRdEWhen working with electrical in older homes that have been updated over the years it is not uncommon to run i... The Roku digital video player is a set-top device that allows you to stream Netflix, Hulu and other digital content to your home television. Roku devices connect to the Internet us...5. Solder, whether leaded or ROHS, introduces amalgam material into the joint. This material is subject to electromigration under current and ion diffusion without current, the different ion species will diffuse/migrate at different rates and directions to create distinct layers of homogenous material, the joints between these layers are ...Remember, though, that if you’re dealing with complex wiring, it’s always best to use a junction box for optimal safety. So there you have it – a complete guide on how to extend a wire without a junction box. Just make sure you take the necessary precautions when working with electrical wiring and follow the steps outlined above.May 11, 2023 · With a pry bar or screwdriver, coax the box away from the stud enough to see the mounting nail or screw. With a metal blade on a reciprocating, oscillating, or keyhole saw, cut the nail or screw. Be careful to avoid hitting the electrical cable. Pull the box out of the hole while leaving the wire in the wall cavity. InvestorPlace - Stock Market News, Stock Advice & Trading Tips Source: Stephanie L Sanchez / Shutterstock.com Today, most electric vehicle (EV... InvestorPlace - Stock Market N...Then, remove about ½” of the plastic sheathing from the individual copper wires. Examine the wiring for signs of damage. Look for burnt wire insulation, cut wires, nicks, or bite marks. Remove any damaged areas before you begin splicing. Slide a piece of shrink tubing over the wire you’re splicing as you’ll need it once you complete the ...Split the sheathing on the cable leaving about 1/4in still covering the wires. Cut the sheathing to remove it and strip off about 3/4 inch of the plastic insulation from the end of each wire. Avoid nicking or scratching the copper wire while removing the insulation. Insert a clamp, with wires attached, into the junction box hole and from inside ...Wires easier handyman outlets familyhandyman roughed identify kerala sheathing Extend electrical wire without junction box Wiring electrical. Electrical Wiring - Part I - YouTube. How to extend and splice electrical wire without junction boxes How to extend electrical wiring then joining it Outlet extend followup junction …I think the point here should be never take electrical advice from a General Contractor. Get your advice from an experienced electrician. There is absolutely no reason to replace all the wiring in the house. Upgrading or moving the service does not require a complete re-wire. Fire is about the only thing that requires a re-wire.For intermediate-sized electrical wires such as #14 copper wire (a 15-Amp electrical circuit) or #12 copper wire (a 20-Amp electrical circuit), you can usually strip about 3/4" of bare wire (special stripping tools are available that won't damage the wire or you can work carefully with wire cutters or a knife), and you can twist your wires ...To make a run for a ceiling fixture, push an electrician's fish tape through the switch hole and down to the source receptacle. Use electrical tape to strap about 6 inches of cable to the fish tape and pull it up through the switch hole. Cut it free from the fish tape and leave about 12 inches on both ends.Begin by slightly pushing out the nails on the box by hand, so that when you place the box against the stud, the tips of the nails lightly pierce the wood. This helps hold the box in place during those first couple crucial strikes of the hammer as you drive the mounting nails into the stud. Continue to 5 of 7 below.To make a run for a ceiling fixture, push an electrician's fish tape through the switch hole and down to the source receptacle. Use electrical tape to strap about 6 inches of cable to the fish tape and pull it up through the switch hole. Cut it free from the fish tape and leave about 12 inches on both ends.If you want to go that route, you'll have to remove the box, and make the connection without a box. – Tester101. Sep 21, 2012 at 12:00. Show 1 more comment. You cannot cover any junction box that still has live wires in it. Your best bet is to either remove the box all together or just put a cover plate on it.3. While extending electrical wire without a junction box is not ideal, it’s crucial to remember that the length of the wire should never exceed the maximum allowed by electrical codes. Overextending wires can lead to voltage drops and other electrical issues, compromising the safety and functionality of your electrical system. 4.Making junction boxes for less than 2 dollars (assuming you have the tools and wire nuts/push connectors already) :-) ---This is a re-upload where at the en...Bring the cables into the box through the clamps. Make a mark on the cable about ½ inch beyond the clamp, withdraw the cable, measure and cut the conductors about 6 inches beyond the mark, then strip the cable’s plastic or metal sheathing back to the mark. Bring the cable back into the box. If it’s a metal box, tighten the cable clamps ...Single Gang Boxes: A total capacity of 18 cubic inches allows for nine #14 gauge wires, eight #12 gauge wires, or seven #10 gauge wires.This is a wires-only capacity. With one device added to the box, subtract two wires in each category. Double Gang Boxes: A total capacity of 34.3 cubic inches allows for 16 #14 gauge wires, 15 #12 …Splice Ground First. Hold the bare copper ground wires with one hand, and line up the ends so they’re even. Twist the ends of the wires together two or three times with lineman’s pliers. If any of the wires are not solid metal but have multiple fine threads or strands, skip this step. Spin on a wire nut until tight.Mar 3, 2021 · Installing a Tyco Electronics no junction box splice connector. https://www.grainger.com/category/ele... ...more. You can't bury the junction box. Obviously the temptation is to seal up the steel box and bury it behind trim or whatever. Can't do it, not allowed. The junction box cover must be accessible without the use of any tools. (other than the two screws holding on the box cover itself, obviously). However, you can make the junction box be dual ...Prepare: Begin by gathering all the necessary tools and materials mentioned earlier. Ensure that the power to the circuit you are working on is turned off at the circuit breaker. Measure and cut: Measure the length of wire needed for the extension and use wire cutters to cut the existing wire to the desired length.Feed the loop through the knockout into the wall cavity. Bend the end of a wire coat hanger to form a hook. Insert it through the hole in the exterior, grab the wire loop in the wall and pull it back through the hole. Pull through at least 12 in. of cable to give yourself plenty to work with. Family Handyman. Step 7.Feed the loop through the knockout into the wall cavity. Bend the end of a wire coat hanger to form a hook. Insert it through the hole in the exterior, grab the wire loop in the wall and pull it back through the hole. Pull through at least 12 in. of cable to give yourself plenty to work with. Family Handyman. Step 7.Connecting Wires Inside the Junction Box. Carefully strip the insulation from the wires and connect them inside the junction box using wire connectors. Follow the manufacturer’s instructions for proper installation. Pay attention to color coding and ensure a secure connection.Either run a new cable or use junction boxes. They make splices/tap kits for repairs on new romex that will work with no slack but I'm not sure what your "black" wire is without seeing it. Some older romex is black. If its 12 gauge and you're splicing it to 12 gauge you will have no problems unless it is aluminum.To install this type of clamp, insert the threaded end into a knockout hole in the box, then thread on the locknut onto the threaded end from inside the box. Tighten the nut with pliers. Insert the cable through the clamp saddle and into the box, and tighten the screws on the saddle to secure the cable.

pendant light| ceiling hook. We installed the hook in the ceiling at the location where we wanted the fixture. First we pre-drilled a small hole and then twisted in the hook, which basically has a screw attached to it. Thankfully our beadboard is made of solid wood, so we felt comfortable that it was strong enough to support the fixture.. Bloomsburg fair senior day 2023

how to extend electrical wire without junction box

Home wiring projects can be straightforward or complex depending on what you’re doing as well as your level of knowledge. Before tackling electrical projects, you should have a bas...3 Answers. Sorted by: You are sunk. Wire that short can't be spliced or extended. The wire must be able to come out beyond the surface of the box at least 3". You will need to reroute these cables to a different junction box somewhere the wiring is able reach with the needed spare length inside the box.A common wire is either a connecting wire or a type of neutral wiring, depending on the electrical circuit. When it works as a connecting wire, the wire connects at least two wires...The cable will also have to be upgraded to 10 gauge. Since the cable will need to be replaced there will be no need for either a junction box or a disconnect. From what I've read, a disconnect would not be required as the water heater is within sight of the breaker (5 feet away). Thanks for the help and feedback.Jan 15, 2024 ... How to Extend Short Wires | Easy Fix Anyone Can Do ... Splice Wires in a Single Gang Electrical Box ... How to Clean copper Wires without Special ...Mar 6, 2019 · 5. Solder, whether leaded or ROHS, introduces amalgam material into the joint. This material is subject to electromigration under current and ion diffusion without current, the different ion species will diffuse/migrate at different rates and directions to create distinct layers of homogenous material, the joints between these layers are ... When it comes to electrical wiring, following the latest codes and regulations is crucial for ensuring safety and preventing potential hazards. Over time, these codes undergo updat...To make a run for a ceiling fixture, push an electrician's fish tape through the switch hole and down to the source receptacle. Use electrical tape to strap about 6 inches of cable to the fish tape and pull it up through the switch hole. Cut it free from the fish tape and leave about 12 inches on both ends.In this electrical DIY guide i will be showing you how to extend short cable. I will take you through step by step, showing you how to splice cables the easy...Aug 30, 2023 · Open splice junction box by Rack-a-Tiers fixes the common (and illegal) problem of exposed wiring electrical connections and makes them safe and up to code e... Splice the ground to the existing ground as well. Run that new, 12-3 wire, to the new outlet, and wire it with the black and red to the brass screws, the white to the silver terminal and hook up the ground. Or, if you don't want half hot outlets but both halves to be switched, you can use 12-2 wire instead. Then, remove about ½” of the plastic sheathing from the individual copper wires. Examine the wiring for signs of damage. Look for burnt wire insulation, cut wires, nicks, or bite marks. Remove any damaged areas before you begin splicing. Slide a piece of shrink tubing over the wire you’re splicing as you’ll need it once you complete the ... Mar 21, 2023 · To install this type of clamp, insert the threaded end into a knockout hole in the box, then thread on the locknut onto the threaded end from inside the box. Tighten the nut with pliers. Insert the cable through the clamp saddle and into the box, and tighten the screws on the saddle to secure the cable. May 5, 2021 · The sheath must extend at least 1/4" into the junction box (bonus points for a bit more and using that to mark where it goes) The separated individual wires must have at least 6" of length inside the box. The wires must extend at least 3" beyond the finished wall surface, unless the box is big enough to work with both hands (e.g. a 10x10 box ... This list shows various electrical boxes and displays the box name and describes the typical application. The most common type of materials that home wiring electrical boxes are made of are: plastic, fiberglass, steel, aluminum and bakealight. The metal boxes come with knock-outs for using conduit such as EMT (electrical metallic tubing) or ... 11 Types Of Electrical Bo And How To Choose One. Aluminum Round Weatherproof Electrical Outlet Bo Manufacturers And Suppliers China Whole Topele. 3 1 2 Round Pan Box Extension Ring Deep Drawn Fixture Earss 4 O C Southwire. Arlington Flbc4500lrbe Gray Plastic Box Extender 4 515 Inch X Com.Sep 8, 2021 ... Metal Vs Plastic Electrical Boxes | Avoid This Common DIY Mistake ... Do I have to have a junction box to splice wires? ... How to Extend Short ...May 19, 2017 · How to Install Junction J-box Extend Wiring in Ceiling for Light Fixture RomexSupport channel with PAYPAL donation: [email protected] COMAN K... Options to Lengthen the Wires: Option 1: Check for extra wire or a service loop behind the box. Gently pull on the wires using pliers to draw more length into the box if available. Option 2: Access the cable feeding into the junction box via attic, basement, or crawl space.Give 1 count of the largest wire size per box to allow for all cable clamps. A cable is several wires wrapped in a sheath. So for example suppose we have two 12/2 cables we must extend. That is the 4 wires from the cables + the 4 wires from the extensions. There are also 4 grounds, but those count as "4 for the price of 1" so they count as 1..